Matronix India Corporation
Matronix India Corporation
Daryaganj, New Delhi, Delhi
GST No. 07AZRPN7834K1ZJ
TrustSEAL Verified
Call 0804763114772% Response Rate
SEND EMAIL

Optical Tonometer

Prominent & Leading Manufacturer from New Delhi, we offer pulsair desktop complete (non contact tonometer), keeler d-kat digital applanation tonometer, schiotz model tonometer, keeler ophthalmoscope bulb, keeler r type applanation tonometer and schiotz tonometer.

Pulsair Desktop Complete (Non Contact Tonometer)

Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
  • Pulsair Desktop Complete (Non Contact Tonometer)
Get Best Quote
Approx. Price: Rs 4.2 Lakh / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Brand NameKeeler
TypeDesktop
Dimensions (HxDxW)475 x 410 x 245mm
Frequency60 Hz, 50 Hz
Measurment Range5mmHg to 50mmHg
Power Supply100-240V
PrinterYes
Working Distance20 mm
Usage/ApplicationHospital
Weight16kg
ColorWhite
Printer TypeThermal line printer

The pulsair Desktop has a small and space saving footprint that combined with the elegant , slim optical mainframe allows it to blend seam lessly into the clinical environment. The openness of the design increases the confidence of both patient and clinician.

Comfort and Speed

Less is more. Pulsair Desktop is uncomplicated and therefore quick to use for the novice and professional alike.

Taking control of tonometry has been easier or faster. Clear user controls and a color video alignment screen combine to set a new standard in usability.

Sophisticated technology

Keeler Pulsair tonometers use advanced optical and sensor technology for positional detection and puff control. Pulsair Desktop and Pulsair intelliPuff have software controls to manage the measurement data. If two consecutive readings are within +/- 1mmHg of each other the Pulsair will inform the user that sufficient readings may have been taken for that eye, saving precious time and increasing patient comfort.

Pulsair Desktop Technical Specifications

Calibrated range

5mmHg to 50mmHg

Displayed accuray

Display accuracy to 1 decimal place e.g. 12.3

Displayed scale

Single line 16 character alphanumeric display

Illumination system

LED infra red

Working distance

20mm

Dimensions

475x410x245mm (HxDxW)

Weight

16kg

Complies with

Electrical safety (medical)BS EN 60601-1:2006, Electromagnetic compatibility EN 60601-1-2:2007, Ophthalmic instruments - fundamental requirements and test mehods ISO 15004-1:2006. Optical radiation hazard ISO 15004-2:2007

Power Supply unit

Switch mode, ( 110-240V)+/- 10% multi plug type compliant to EN 60601-1 EN 6100-6-3

Power supply output

30 VA (12V DC 2.5A)

Frequency

50/60Hz

Printer

Thermal line printer

 

Request
Callback


Additional Information:

  • Production Capacity: 100
  • Delivery Time: 15 days
Yes! I am Interested

Keeler D-KAT Digital Applanation Tonometer

Keeler D-KAT Digital Applanation Tonometer
  • Keeler D-KAT Digital Applanation Tonometer
  • Keeler D-KAT Digital Applanation Tonometer
  • Keeler D-KAT Digital Applanation Tonometer
  • Keeler D-KAT Digital Applanation Tonometer
  • Keeler D-KAT Digital Applanation Tonometer
  • Keeler D-KAT Digital Applanation Tonometer
  • Keeler D-KAT Digital Applanation Tonometer
Get Best Quote
Approx. Price: Rs 85,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
UsageHospital
BrandKeeler
ModelD KAT
ColorBlack
Weight0.3kg
measurement range5-65 mmHg (0.66-8.46kPa)

Designed and manufactured in the UK to the exacting standards you’d expect from a keeler instrument. The keeler D-KAT delivers reliability and ease if use.

The LED display and internal electronics allows the fast accurate measurement of IOP- intraocular pressure. With less moving parts, the D-KAT is more reliable , accurate and recalibration takes just seconds.

Specification

Keeler digital T type for haag streit type illumination systems

Fitted to the guide plate on the optical axis for the microscope and illumination unit arm

Keeler digital R type for some zeiss type and haag streit type illumination systems

Mountable on post on microscope

 

 

Installation

Assembled on the guide plate on the slit lamp arm or mounting post

measurement range

5-65 mmHg (0.66-8.46kPa)

measurement deviation

0.49 mN or 1.5% of measurement value, whichever is the greater

Operating temperature range

From 10degree C to 35degree C

Reverse span (Hysteresis)

<0.49mN

Net weight

 

keeler digital T type

0.37 kg (without accessories)

Keeler digital R type

0.58 kg (without acessories)

Part Numbers

 

keeler digital T type

2414-p-2032

Keeler digital R type

2414-p-2042

Request
Callback


Additional Information:

  • Production Capacity: 100
  • Delivery Time: 15 days
Yes! I am Interested

Schiotz Model Tonometer

Schiotz Model Tonometer
  • Schiotz Model Tonometer
  • Schiotz Model Tonometer
  • Schiotz Model Tonometer
  • Schiotz Model Tonometer
  • Schiotz Model Tonometer
  • Schiotz Model Tonometer
  • Schiotz Model Tonometer
Get Best Quote
Approx. Price: Rs 12,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Automatic gradeManual
Length1 Feet
Scale TypeAngled, Straight
UsageClinic
BrandSchiotz
MaterialSS

Our firm specializes in offering an excellent collection of Schiotz Tonometer (Riester). It consists of a curved footplate which is placed on the cornea of a supine patient. This product is manufactured using topmost grade raw-material and sophisticated technology in conformity with the certified industry norms. In order to deliver the defect free range at clients'' end, this product is checked against the various parameters of quality before supply set by industry. We offer this product at most affordable rate.

Features:
  • High functionality
  • Smooth performance
  • Industry approved design
Request
Callback
Yes! I am Interested

Keeler Ophthalmoscope Bulb

Keeler Ophthalmoscope Bulb
  • Keeler Ophthalmoscope Bulb
  • Keeler Ophthalmoscope Bulb
  • Keeler Ophthalmoscope Bulb
  • Keeler Ophthalmoscope Bulb
  • Keeler Ophthalmoscope Bulb
  • Keeler Ophthalmoscope Bulb
  • Keeler Ophthalmoscope Bulb
Get Best Quote
Approx. Price: Rs 4,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Power20 W
Brandkeeler
IP RatingIP55
Base TypeG4
Country of OriginMade in India

Keeler Bulbs
All Keeler instruments use genuine Halogen and Xenon technology, yielding a brighter, whiter illumination and a longer life. Look at the bottom of your bulb to identify if your instrument is 2.8 V (Dry cell battery) or 3.6 V (Rechargeable battery).

Request
Callback


Additional Information:

  • Production Capacity: 100
  • Delivery Time: 15 days
  • Packaging Details: in box
Yes! I am Interested

Keeler R Type Applanation Tonometer

Keeler R Type Applanation Tonometer
  • Keeler R Type Applanation Tonometer
  • Keeler R Type Applanation Tonometer
  • Keeler R Type Applanation Tonometer
  • Keeler R Type Applanation Tonometer
  • Keeler R Type Applanation Tonometer
Get Best Quote
Approx. Price: Rs 80,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
UsageHospital
BrandKeeler
ModelR Type
ColorBlack
Weight0.3kg
measurement range5-65 mmHg (0.66-8.46kPa)

Designed and manufactured in the UK to the exacting standards you’d expect from a keeler instrument. The keeler D-KAT delivers reliability and ease if use.

The LED display and internal electronics allows the fast accurate measurement of IOP- intraocular pressure. With less moving parts, the D-KAT is more reliable , accurate and recalibration takes just seconds.

Specification

Keeler digital T type for haag streit type illumination systems

Fitted to the guide plate on the optical axis for the microscope and illumination unit arm

Keeler digital R type for some zeiss type and haag streit type illumination systems

Mountable on post on microscope

 

 

Installation

Assembled on the guide plate on the slit lamp arm or mounting post

measurement range

5-65 mmHg (0.66-8.46kPa)

measurement deviation

0.49 mN or 1.5% of measurement value, whichever is the greater

Operating temperature range

From 10degree C to 35degree C

Reverse span (Hysteresis)

<0.49mN

Net weight

 

keeler digital T type

0.37 kg (without accessories)

Keeler digital R type

0.58 kg (without acessories)

Part Numbers

 

keeler digital T type

2414-p-2032

Keeler digital R type

2414-p-2042

Request
Callback


Additional Information:

  • Production Capacity: 100
  • Delivery Time: 15 days
Yes! I am Interested

Schiotz Tonometer

Schiotz Tonometer
  • Schiotz Tonometer
  • Schiotz Tonometer
  • Schiotz Tonometer
Get Best Quote
Approx. Price: Rs 12,000 / PieceGet Latest Price
Product Brochure

Product Details:

Measurement Range0 to 20
Item Weight5.5 g,7.5 g,10 g
Model Number5110
llumination SystemLed Infra Red
Scale TypeAngled,Straight
Working distance11mm

Leveraging on our industrious professionals, we are offering a supreme quality range of Hospital Tonometer. Offered meter is manufactured using optimum quality raw material and latest technology by our skilled professionals. Besides, this meter is made available in various specifications. This meter is highly appreciated among our clients for its precise design and durability. We provide this meter at very competitive price to our clients.

Features:

  • Instruments according to Prof. Schiotz for measuring eye pressure.
  • Needs almost no servicing, ensues smooth operations for years.
  • Highly accurate weights to give correct measures.
  • Jewel operated, complete with three weights.
  • International standard built.
  • Tonometer complete in case
A masterpiece of precision mechanics! Highly precise eye tonometer according to Prof. Schiotz for measuring intra-ocular pressure. Itsreliability and durability makes this quality measuring instrument indispensable in every ophthalmologist’s practice and eye clinic.

• High quality agate bearing for an extremely long service life
• Precision measurement on a scale of 0 to 20 subdivisions and 0 to -1 sub-divisions
• Perfect reading of the scale with red pointer
• All vital parts are made of stainless steel, other parts are chrome-plated
• Complete in a black deluxe case with velvet-look inserts
• Supplied with three weights (5.5 g, 7.5 g, 10 g) and a conversion table Specification 5, polished weights, with inspection certificate schiötz A, with straight scale No. 5110 schiötz B, with inclined scale No. 5111 Specification 3 schiötz C, with inclined scale No. 5112

Sciotz Tonometer Reister Tonometer
Request
Callback


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
Yes! I am Interested

Matronix Applanation Tonometer

Matronix Applanation Tonometer
  • Matronix Applanation Tonometer
Get Best Quote
Approx. Price: Rs 40,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Prism Diameter7 Mm
Range of Measurement0 Mmhg - 80 mhg
Automatic GradeAutomatic
Weight300 G
UsageHospital
BrandMatronix

Owing to our experience and knowledge in this domain, we are engaged in offering a supreme quality of Matronix Applanation Tonometer. This meter is manufactured using high grade raw-material and progressive technology in compliance with the set industry standards. Offered meter is highly acclaimed among clients for its fine finish, optimum quality, corrosion-resistance and durability. The offered meter is checked by our experts against various parameters of quality.

Features:
  • Measurement under slit lamp microscope can have two effects, insect the eye and measure the intraocular pressure,
  • Numerical value is precise, The tonometer's own error is only 0. .66kpa.
  • Get numerical value of IOP directly. no need to look up tables or do matrixing, And Pt:="Pie lgP lgP 0=0.56k, Normal k=0.0215, then : Pt: P0=1.028
  • The hardness of sclera does not affect the numerical value. Change of the volume of eyeball is only 0.56 mm3.
  • Combine with the measurement method of Schiotz tonometer, counting the hardness of sclera can be done
  • The Measuring-pressure can be to calibrated. guarantee the stability over a long period of time and reliability of measurement.
Request
Callback
Yes! I am Interested

Reister Tonometer Germany

Reister Tonometer Germany
  • Reister Tonometer Germany
Get Best Quote
Approx. Price: Rs 12,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
UsageHospital
Modelreister tonometer germany
Colorsilver
Precision measurement0 to 20 subdivisions and 0 to -1 sub-divisions
Supplied with three weights5.5 g,7.5 g,10 g

A masterpiece of precision mechanics! Highly precise

eye tonometer according to Prof. Schiötz for measuring

intra-ocular pressure. Its reliability and durability makes

this quality measuring instrument indispensable in every

ophthalmologist’s practice and eye clinic.

• High quality agate bearing for an extremely long

service life

• Precision measurement on a scale of 0 to 20 subdivisions

and 0 to -1 sub-divisions

• Perfect reading of the scale with red pointer

• All vital parts are made of stainless steel, other parts

are chrome-plated

• Complete in a black deluxe case with velvet-look inserts

• Supplied with three weights (5.5 g, 7.5 g, 10 g) and a

conversion table
Request
Callback


Additional Information:

  • Production Capacity: 50
  • Delivery Time: 15 days
Yes! I am Interested
X

Product Videos

Watch More Videos

Explore More Products

View All Products




Reach Us
Sudhir Rai (Manager)
Matronix India Corporation
4736/23 Second Floor,,,Ansari Road,,Darya Ganj, Opposite Bank of India, 1566, Kucha Dakhani Rai, Faiz Bazar, Daryaganj,110002, New Delhi - 110002, Delhi, India


Call Us


Send E-mail